Plan Review Detail
Review Status: Active
Review Details: PREAPPLICATION MEETING
Plan Number - T22PRE0049
Review Name: PREAPPLICATION MEETING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2022 | MROSS2 | FIRE | REVIEW | Completed | 507.1 Required water supply. An approved water supply capable of supplying the required fire flow for the protection shall be provided to premises on which facilities, buildings or portions of buildings are hereafter constructed or moved into or within the jurisdiction. 507.3 Fire Flow. Fire-flow requirements for buildings or portions of buildings and facilities shall be in accordance with Appendix B of the IFC Michael Ross Tucson Fire Department 520-837-7082 Michael.Ross2@tucsonaz.gov |
| 03/15/2022 | BILLIE LEE | COMMENTS | COMMENTS | Active | |
| 03/15/2022 | JOHN BEALL | M&C Public Hearing 4 Plan Amendment | Set M&C Public Hearing Date | Active | |
| 03/15/2022 | NICHOLAS ROSS | ZONING | REVIEW | Completed | Rezoning Pre-Submittal Transmittal FROM: Nick Ross PDSD Zoning Review PROJECT: Rezoning Pre-submittal meeting T22PRE0049 Address: 2211 S Mission Rd Parcel(s): 118-07-005T Existing Zoning: R-1 Proposed Zoning: C-2 Existing Use: Vacant Proposed Use: General Merchandise Sales, Excluding Large Retail Establishments/Admin & Professional Office TRANSMITTAL DATE: March 15, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Proposed use and use-specific standards: 4.9.9.B.1(Gen Merch Sales) & 4.9.13.P (Admin & Prof Office) 3. Development standards: 30 ft building height (Scenic Corridor Zone) 4. Perimeter yard setbacks: Adjacent to R-1 and MH-1 zones = 1 ½ H. Adjacent to C-2 zone = 0. 5. Applicable street setbacks: Mission Rd is a designated Scenic Corridor. Compliance with the buffer area and building heights will dictate street setback. 6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445 7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698 8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov 9. Additional comments: a. It's unclear the intended use of the outdoor yard. Use-specific standards may limit where certain merchandise can be displayed in this area. b. Mission Rd is designated as a Scenic Corridor. Compliance with UDC Section 5.3 will be required. 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at nicholas.ross@tucsonaz.gov. |
| 03/16/2022 | LOREN MAKUS | ELECTRICAL ENGINEERING | REVIEW | Completed | 1. Flood hazard on the site is limited to 500-year floodplain. There will be no affect on proposed development. 2. Proposed buildings seem to be outside of erosion hazard setback for adjacent washes. 3. First flush retention is required and can be met by maximizing water harvesting with lower impact development standards. 4. This project discharges to RFCD property and the district will review the development plans for the site. The district may request detention as a condition of receiving the discharge. We recommend discussing development proposals and drainage with the district early in the process. 5. Access management guidelines require 80 feet between adjacent driveways. Provide adequate separation from driveway on adjacent property. Loren Makus loren.makus@tucsonaz.gov |