The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: T22PRE0032
Parcel: Unknown

Address:
1410 W AJO WY

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0032
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2022 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T22PRE0032 (1410 W Ajo Wy – Quick Oil Change)

TRANSMITTAL DATE: 3/01/2022



1.COMMENT: This project will require a development package and a lot combination. Information on the Development package can be found at.
https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf

Information on the Pima County lot combination can be found at:
https://www.asr.pima.gov/Downloads/Forms/ComboRequest.pdf

All parcels will need to be combined prior to approval of Development Package.

2.COMMENT: Automotive minor service and repair is permitted in the C-1 zone through a zoning examiner special exception procedure only. Information on this procedure can be found at

https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-1048

Use specific standards 4.9.4.F.2, .3, .4, & .5 and 4.9.13.O of the Unified Development Code apply to this project.

3.COMMENT: Provide pedestrian access from building to Ajo Wy. 7-01.3.3A Technical Standards Manual.




For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
03/02/2022 MROSS2 COT NON-DSD FIRE Completed 507.1 Required water supply.

An approved water supply capable of supplying the required fire flow for the protection shall be provided to premises on which facilities, buildings or portions of buildings are hereafter constructed or moved into or within the jurisdiction.



507.3 Fire Flow.

Fire-flow requirements for buildings or portions of buildings and facilities shall be in accordance with Appendix B of the IFC.


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
03/02/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Quick Oil Change
ACTIVITY NO. T22PRE0032
ADDRESS/PARCEL: 1410 W Ajo Way
ZONING: C-1

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.
• 10’ Street landscape border required along both Ajo Way and S Holiday Isle Blvd
• Parking area as designed does not mitigate heat island effect

Placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40’ of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself to provide shade on asphalt. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
03/03/2022 DSTIFFE1 COT NON-DSD TRAFFIC Completed 1. If existing sidewalk is a minimum of 4 Ft wide and meets current ADA standards, it can remain.
2. Any out of compliance sidewalk, curb, or curb access ramps, will need to be brought up to standard.
3. New curb to be installed per P.A.G. standard 209
4. New curb returns on Ajo Way are to have a 30' radius
5. New curb returns on Holiday Isle are to have an 18' radius
6. New curb access ramps are to be installed at new curb returns
7. An ADA compliant 60" X 60" landing will need to be built at the point on Holiday Isle where new sidewalk will tie-in perpendicularly to existing
8. Any existing curb cuts not used will need to be closed with new curb per P.A.G. standard 209
03/03/2022 SBLOOD1 ENGINEERING REVIEW Completed 1. Using Low Impact Development design and water harvesting provide balanced basin detention and first flush retention. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With edits to the manual found: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
2. Maximize water harvesting.
3. Show the solid waste vehicle maneuverability, waste stream calculations, and approved enclosure per Technical Standards Manual section 8.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
03/03/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T22PRE0032 - 1410 W AJO WY - Site Two-bay, drive-thru oil change facility

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov