Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T22PRE0017
Parcel: Unknown

Address:
6420 E 22ND ST

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0017
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/09/2022 SBLOOD1 ENGINEERING REVIEW Completed 1. No comments

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
02/09/2022 MROSS2 COT NON-DSD FIRE Completed None


Michael Ross
Tucson Fire Department
520-837-7082
Michael.Ross2@tucsonaz.gov
02/09/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Jim Click Hyundai - Eastside
ACTIVITY NO. T22PRE0017
ADDRESS/PARCEL: 135-02-001A
ZONING: C-1/2


Depending on expansion calculations, the following may be required;

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

Placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40’ of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself to provide shade on asphalt. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-manual-board-version-201511.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
02/09/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 300 - 330 pm - T22PRE0017- 6420 E 22ND ST - Site
Jim Click Hyundai

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
02/10/2022 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers; Planner

PROJECT: Thursday Pre-submittal meeting T22PRE0117
Address: 343 S SCOTT AV
Parcel(s): 11717044B
Zoning: HC-3
Existing Use: Administrative Office
Proposed Use: FLD Subdivision

TRANSMITTAL DATE: 06/09/2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-07.0.0: Final Plat, Block Plat, Minor Subdivision, and Condominium Plat Applications.
2. Single Family homes are an allowed use in the HC-3 zone.
3. A Condo Plat may be a simpler route than the FLD process.
4. The FLD will require a Tentative Plat and Final Plat, a Condo Plat will require only a Final Plat.
5. Primary access off of an unnamed alley is not permitted, DTM will need to sign off on alley access.
6. On-street parking is not allowed, however, historic may be able to waive this requirement. I recommend reaching out to Jodie Brown or Michael Taku on what historic may be able to waive. (jodie.brown@tucsonaz.gov/(520) 837-6968, michael.taku@tucsonaz.gov/(520) 837-4963)
7. FLD subdivisions are required to have a minimum of 109 sf/unit.
8. Building may require the shared walls separating the units to be fire-rated.
9. The proposal is adequate to proceed with submittal of a FLD Subdivision or Condo Plat Minor Subdivision application.
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Minor Subdivision review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at samuel.rogers@tucsonaz.gov or (520) 837-6932.
02/11/2022 NROSS1 COT NON-DSD TRAFFIC Completed 1. If expansion exceeds 25%, full site compliance is required