Plan Number: T22PI00012
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T22PI00012
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2022 GARY WITTWER DOT LANDSCAPE REVIEW Reqs Change DTM Landscape


1. There are several native plants (saguaros and others) at the entrance on Alvernon, what is the plan for this vegetation as it looks like it will be demolished while upgrading the entrance with the new curb returns and drainage improvements?



David Marhefka, PLA
da’-vid mär-hef’-ka
Landscape Architect Project Manager
City of Tucson
Department of Transportation and Mobility
(m) 520-403-5074
07/25/2022 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
07/25/2022 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change DTM Traffic Engineering

- Sheet 6: I think last typical section (Sta 604+) should be calling out as Alvernon Way, not Aeronautical Way
- Sheet 6: Is intent of 10 ft wide sidewalk to be for a multi-use path? This is not shown on Sheets 18 or 19
- Sheet 17: PM Notes 1,2,3,7 refer to PC standards. Should refer to COT standards. Note 2 should use 520-791-3154 phone number. Note 1 should refer to the PC/COT Signing and Pavement Marking Manual instead of old Pavement Marking Manual. https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL-Pima-County_City-of-Tucson-Signing-and-Pavement-Marking-Manual-2020-First-Edition_linking_nocomments-12_21.pdf
- Sheet 17: Signing Notes 1 & 2 should refer to the PC/COT Signing and Pavement Marking Manual instead of old Signing Manual
- Signing Note 12 can be removed
- Signing Note 14: Delivery of salvaged signs should be coordinated with COT Sign Shop at 4004 S Park Ave (520-791-3154)
- Sheet 18: Left turn bay taper appears substandard. For 45 mph, should be T=W*S = 12*45 = 540 ft
- Sheet 18: Right turn bay taper looks good
- Sheet 18: Turn bay gaps and storage lengths appear to meet minimum requirements in PC/COT Signing and Pavement Marking Manual Appendix A
- Sheet 18: COT utilizes the YDS4-D40/D40 markings for the yellow separator stripe
- Sheet 19: COT street name signs refer to Signing and Marking Manual Std 6.1.6 (6.1.1 is PC)
- Sheet 19: W3-1 Stop Ahead sign could be moved closer to intersection per MUTCD Table 2C-4
- Sheet 19: Turn bay tapers, gaps, and storage lengths appear to meet minimum requirements in PC/COT Signing and Pavement Marking Manual Appendix A


Thank you,
Greg Orsini, P.E.
520-8376617
greg.orsini@tucsonaz.gov
07/25/2022 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines. Also, provide utility clearance letters for the fiber optic facility owners identified on the paving plans.
07/25/2022 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
07/25/2022 ERNIE ENCINAS DOT_ELEC REVIEW Approved
07/25/2022 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change DTM Engineering

July 25, 2022

SUBJECT: Alvernon Way/Aeronautical Way Intersection Improvements

PROJECT REVIEWER: Richard Leigh, DTM Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments.


1. Add the plan number “I-2022-014” in the title block of each sheet.

2. Add PIA activity number “T22PI00012” on coversheet.

3. Use current COT DTM Plan Template which can be found at htps://www.tucsonaz.gov/tdot/engineering

4. A portion of this project is located within a FEMA mapped floodplain. Please submit a completed TDOT Floodplain Use Permit Application.

5. Sheet 13 & 14: Indicate limits of the proposed clearing and grubbing limits and provide grading details, finish grading and compaction requirements.

4. Sheet 13 & 14: Provide complete details of the proposed rock rip-rap swale between Sta. 610.+50 LT and 611+83 LT,

5. Sheet 3: The City of Tucson DTM does not allow CMP within the public rights-of -way. RCP will have to be used in the proposed culvert crossing.

6. Sheet 20: Provide ADEQ SWPP notes.

7. Refer to redline drawings for comment details and additional comments.

If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov.
07/25/2022 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed Submit Utility Notification Receipts for the Utilities listed on the DTM Utility Clearance Letter which can be found at https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines. Also, provide utility clearance letters for the fiber optic facility owners identified on the paving plans.
07/25/2022 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
07/25/2022 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review