Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T22PI00008
Parcel: Unknown

Address:
7531 S WILMOT RD

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T22PI00008
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/28/2022 GARY WITTWER DOT LANDSCAPE REVIEW Reqs Change DTM Landscaping

1. Add the notes for Planting in the ROW and Private Irrigation in the ROW to the plans.

City of Tucson
Department of Transportation & Mobility
Standard Notes for Planting in Right of Way

1. It is the owner’s responsibility to keep the Sight Visibility Triangles (SVT), and the pedestrian access area clear of vegetation at all times, per Unified Development Code Technical Standards Manual section 10.
2. It is the owner responsibility to keep a 5’ wide (minimum) by 7’ tall clear pedestrian access open across the entire property.
3. It is the owner responsible to keep vegetation from growing past the curb line clear, and keep a 15’ high clear zone over the travel lane.
4. Final plant locations must be in compliance with all utility setback requirements.
5. The owner understands that if the City of Tucson Department of Transportation & Mobility or any utility company needs to work within the ROW in the landscaped area, plants and irrigation may be destroyed without replacement or repair.
6. The owner takes full liability for this landscape and irrigation, and any damage to roadway, sidewalk and utilities.
7. The only private irrigation equipment that is allowed within the ROW are lateral lines, tubing and emitters that are not under constant pressure. All other equipment must be on private property (excluding water meter).
8. Contractor to obtain a ROW permit prior to construction within the ROW.


City of Tucson, Department of Transportation and Mobility
Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way

1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways.
2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way.
3. The HOA/Owner will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member.
4. Minimize the number of roadway crossings.
5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting.
6. Irrigation lines shall be placed in ductile iron sleeves.
7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT.
8. HDPE continuous line (no joints under the pavement)
9. Irrigation lines shall have a minimum of thirty (30) inches of cover.
10. Detectable marking tape shall be installed.
11. Curb shall be marked/stamped with “IS” (Irrigation System) and/or placard at back of curb.



Thanks,

David



David Marhefka, PLA
da’-vid mär-hef’-ka
Landscape Architect Project Manager
City of Tucson
Department of Transportation and Mobility
(m) 520-403-5074
06/28/2022 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
06/28/2022 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
06/28/2022 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
06/28/2022 JIM FEMLING DOT STREET MAINTENANCE REVIEW Completed
06/28/2022 ERNIE ENCINAS DOT_ELEC REVIEW Completed
06/28/2022 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change June 28, 2022

SUBJECT: La Estancia – Parcel 8

PROJECT REVIEWER: Richard Leigh, DTM Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments.


1. Add the plan number “I-2022-008” in the title block of each sheet.

2. Add PIA activity number “T22PI00008” on coversheet.

3. Sheet 1: Provide a place holder for the subdivision plat recording sequence number.

4. Call out any proposed private irrigation lines, delineate and label irrigation easements. Provide DTM private irrigation installation notes.

5. Indicate locations of no parking signs.

4. Sheet 3: Revise Scupper Detail to indicate placement of barricade railing along the backside of scupper.

5. Sheet 3: Revise Scupper detail schedule to indicate number of cells.

6. Sheet 9: Provide complete details and a cross section of the proposed storm drain at 13+70 Placita Cofrecito.

7. Refer to redline drawings for additional comments and comment details.

If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov.
06/28/2022 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed
06/28/2022 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
06/28/2022 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review