Permit Number: T22MH00020
Parcel: 115170880

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T22MH00020
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/18/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
04/19/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22MH00020
Mobile home
1320 N APACHE DR Zoning R-2

TRANSMITTAL DATE:? April 19,2022


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1.COMMENT: Per Use-specific standard 4.9.7.B. 6. A manufactured housing unit is not considered a dwelling for the purposes of this section, unless the following standards are met or a subdivision plat that has been clearly identified for manufactured housing has been approved and permits for manufactured homes have been issued for 25% or more of the lots prior to December 27, 2000:
a. It is placed on an excavated and backfilled foundation (ground set). If the home is located in a floodplain, the bottom of the lowest floor joist shall be a minimum of one foot above the 100-year/base flood elevation, and the foundation of the home shall be placed on the fill ;
b. No more than eight inches of perimeter skirting wall shall be visible from the streetfrontage of the property. The perimeter skirting wall shall match the exterior color of the home;
c. The exterior siding materials shall be either hardboard, vinyl, or stucco;
d. Concrete or masonry steps shall be provided for the entry on the street side of the dwelling;
e. All entry doors on the street side of the dwelling shall be inward-swinging doors; and,
f. The roofing style and materials shall be either flat roof (Pueblo), steel rib roof, or shingle or tile roof with a 3:12 roof pitch or greater. All pitched roofs, except those that are disguised by a parapet, shall have a minimum six inch eave on all sides of the dwelling.

2.COMMENT: Provide the floor plan of the proposed dwelling. Also please provide the number of bedrooms or a floor plan for the existing SFR


3.COMMENT: Additional comments may be forthcoming

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
04/19/2022 IMONSHI1 ENGINEERING REVIEW Passed
04/19/2022 PCAMARE1 NPPO REVIEW Passed
05/26/2022 ARUIZ1 WWM REVIEW Passed