Permit Number: T22CM07602
Parcel: 116182300

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM07602
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/04/2022 ANY BUILDING-RESIDENTIAL REVIEW Active
10/05/2022 JCARLTO1 NPPO REVIEW Passed
10/05/2022 SHASEMA1 ENGINEERING REVIEW Passed
10/18/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM07602
Addition
1015 W ALAMEDA ST Zoning R-2

TRANSMITTAL DATE:?October 18, 2022


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf This shall in include:
a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements. (Lot coverage must include vehicular use area whether improved or unimproved) Clarify why there is a negative 300 sf in the lot calculation.
b. Zoning of adjacent parcels
c. Setback dimensions

2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall.

3. COMMENT: Clarify if a portion of the existing work shop is to be demolished if so Historic review is required.
The Pima County Assessor’s effective construction date for your building or structure is 1919. The actual construction date may be earlier.
Buildings, portions of buildings or structures that are 50 years of age or older must be architecturally documented prior to demolition. Documentation will be reviewed and approved by the Historic Preservation Office before a permit is issued.
Demolition (Historic and Older Structures) Application and General Information may be downloaded (PDF) at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements
Return completed documentation to PDSDHistoric@tucsonaz.gov. Applicant will be contacted within 5 working days if additional materials are required for review.


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov