Permit Number: T22CM07441
Parcel: 117080550

Address:
808 S 4TH AV

Review Status: Active

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM07441
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
09/28/2022 SHASEMA1 ENGINEERING REVIEW Passed
10/05/2022 JCARLTO1 NPPO REVIEW Passed
10/17/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM07441
808 S 4th Ave – HR-3
Pergola & fence addition (1st Review)

TRANSMITTAL: October 17, 2022
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-3 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6.

1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Provide a setback dimension from the proposed pergola to the north property line.

Historic review required for the pergola & fence addition. Historic review is required and must be approved prior to approval of this building plan. Historic application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf, and is a separate submittal from the building plans submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using Submission Type “Historic Review”.


If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
10/20/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Locate and size reinforced footings for supporting live and dead structural loads, R401.2 or provide an engineer’s calculation, design and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1.

2. Provide a complete cross-section detail from foundation to roof assembly with fastening of each component, R106.1.1.

3. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.

4. A special inspection request is required with the permit application for field welding, R109.2.