Permit Number: T22CM07360
Parcel: 129051530

Address:
2044 E 17TH ST

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM07360
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/30/2022 JVINCEN1 FIRE REVIEW Approved
10/11/2022 WILDAN BUILDING-COMMERCIAL REVIEW Reqs Change Activity Number: T22CM07360


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

Denied
Sheet 2 See S2.0 for redlined comments
Sheet 2 Provide Occupancy of existing structure. Provide Type of Construction of existing construction. Provide floor plan of existing structure. Provide exit doors on existing structure showing exit path from structure.
Sheet 2 Will there be any electrical lighting or outlets provided under new awning?
Provide shear wall calcs for new awning.
Sheet S2.0 provide structural calcs showing the vertical leg of the existing truss is designed to support the weight of the new framing and roofing.
Sheet S2.0 Provide detail of existing wall which is carrying the load from the new roof.Show existing foundation supporting the wall supporting the trusses. Provide ES Report number for roofing material being used. Provide flashing detail at existing wall and new awning roof.
Sheet S2.0 Key note 8 is not included
Sheet S2.0 Provide special inspection for field welding.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
10/12/2022 LEVANS2 ENGINEERING REVIEW Approved
10/18/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T22CM07360
2044 E 17th St – C-2
Awning Addition – (1st Review)

TRANSMITTAL: October 18, 2022

This site is located in C-2 Zone (UDC Article 4.7.21).

1. The proposed awning addition requires a new development package. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements the checklist for Minor Development Changes to Existing Commercial/Industrial Sire, found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf, must be submitted and approved prior to approval of this building plan. The DP is a separate submittal from the building plans and is submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type “Site Review”.


If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/18/2022 VVERA1 OUT TO CUSTOMER Completed