Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM07328
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/23/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
| 09/28/2022 | PAUL CAMARENA | ZONING | REVIEW | Passed | |
| 10/04/2022 | JCARLTO1 | NPPO | REVIEW | Passed | |
| 10/10/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | 1. Show the mast height on the electrical riser diagram providing 8’ clearance above the Porch roof, E3604.2.1. 2. Provide an exterior outlet at grade level located at both the front and back of the dwelling, E3901.7. 3. Show at least one wall switch controlled light at outdoor entrances or exits, E3903.3. Include the Dining Room door. 4. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. Update note #6. |