Permit Number: T22CM07301
Parcel: 13705375A

Address:
842 W UTAH ST

Review Status: Active

Review Details: RESUBMITTAL

Permit Number - T22CM07301
Review Name: RESUBMITTAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/17/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM07301
842 W Utah St - R-2
Detached Storage Container (2nd Review)

TRANSMITTAL: October 17, 2022

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .

1. This comment was not addressed correctly. This site also consists of the house and property located at 834 W Utah St. Show the entire parcel and all structures on the plot plan and include all structures in the lot coverage. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.

2. Provide setback dimensions from the post supporting the carport to the north and west property line and provide heights for the carport from design grade to the point were the columns/beams meet the roof. The required perimeter yard setback is based on 6’-0” or 2/3 the height, greater of the two. Also the structure is not allowed within the utility easement.

3. Provide a lot coverage calculation on the plot plan. The storage container shall be included in the lot coverage

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
10/20/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change CARPORT SECTIONS - DETAILS:
1. Show the Post Section Detail with #4 rebar in the footing, R403.1.
2. Notate and specify the size of columns with #4 rebar reinforcement, R317.1.
3. Show roof (uplift resistance) rafter fasteners (H2.5) with appropriate uplift capacity, R802.11 amended.
4. Show any ledger fasteners with stucco removal between wall studs and ledger.

Provide a clear and concise construction plan set. Sample Porch (Carport) plans are available at https://www.tucsonaz.gov/pdsd/residential-permits