Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM07213
Parcel: 126130070

Address:
4601 E 12TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM07213
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena

PDSD Zoning Review Section



PROJECT: T22CM07213

Addition

4601 E 12TH ST Zoning R-1



TRANSMITTAL DATE:?September 21, 2022





COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.





1.COMMENT: Clearly show everything on site. From 2014 and on there is an addition that was built on the north and east portions of the main dwelling. Please provide permit documentation for these additions. If no permits are available include them in this next submittal. It appears that the carport addition on the east side of the property is not going to be meeting setbacks.

2.COMMENT: The minimum side and rear setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure. A Design Development Option (DDO) can be used to reduce the required setback if the structure is setback 1ft from the property line, if the structure is less than 1ft from the property line a variance will be required.



3.COMMENT:Additional comments may be forthcoming.



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
09/21/2022 SHASEMA1 ENGINEERING REVIEW Passed
10/03/2022 JCARLTO1 NPPO REVIEW Approved
10/14/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM07213

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Inconsistent information. Revise the details (pg 6 of 6) to reflect 2x6 wall studs. Some of the details indicate 2x4 wall studs.


BUILDING REVIEW COMMENTS:
Denied
1. Obsolete reference. Revise plans (pg 2 of 6) truss loading note #5 to reference ICC. ICBO merged with ICC in 2003 and no longer exists.
2. Inconsistent seismic design category. Revise plans (pg 2 of 6) structural notes to reference seismic design category B. There are two sets of structural notes on this page, one reference seismic design category B and one references seismic design category C.
3. 2008 IRC - 314.2.2. Revise plans to indicate smoke alarms are provided and are compliant with the locations noted in section 314.3.
4. 2008 IRC - Table N1102.1.2. Provide fenestration U-Factor and SHGC.


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Denied
1. 2018 IRC - E3901.12. Revise plans to include a GFCI protected receptacle outlet on the exterior of the house to serve the HVAC equipment.


PLUMBING REVIEW COMMENTS:
N/A



If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov