Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM07163
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/19/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
| 09/20/2022 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T22CM07163 / Shed addition Plot Plan Review (1st Review) 3630 S Clark Av / R-2 TRANSMITTAL DATE: 09/20/2022 COMMENT: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone. The minimum setback to the side and rear yards are 6’ or 2/3 * Height (whichever is greater). The applicant is proposing a shed with a height of 8’ and a setback of 3’ from both the north and east property lines. DDO Required, contact Mark Castro at Mark.Castro@tucsonaz.gov or by phone at (520) 837-4979. COMMENT: Provide a correct north arrow on the next submittal. COMMENT: Provide one updated lot coverage calculation, the other can be removed. For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 09/20/2022 | IMONSHI1 | NPPO | REVIEW | Passed | |
| 10/05/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T22CM07163 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. Update the 2012 entries. Structures built without a permit may require alteration for building code compliance. Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits SITE PLAN: 1. Indicate the location and size of utility lines near the structure, R106.1.1. Show the utility lines requiring upgrade or replacement. STRUCTURAL PLANS: 1. Provide a complete Roof Framing Plan showing rafter sizes and spacing in compliance with Table R802.4. 2. Show roof structural members with rafter ties (or ceiling joists) and collar ties (ridge straps) when the roof pitch is equal or greater than 3” to 12”, R802.3. SECTIONS - DETAILS: 1 Provide a wall detail showing a 6” minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5. Also, show ½” @ 6’ O.C. anchor bolts with embedment into a 12” x 12” continuous foundation with #4 bear reinforcement. This may require a design with concrete stems. 2 Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |