Permit Number: T22CM07078
Parcel: 116277640

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM07078
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/04/2022 WBERGER1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Wyatt Berger
Planner

PROJECT: T22CM07078
3170 W Tumamoc Dr
New SFR (1st Review)

TRANSMITTAL DATE: September 15, 2022

This site is in the -1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) and is subject to use-specific standards 4.9.7.B.5-.9.

1. Per tentative plat S02-007, a grading plan separate from the building plan submittal is required. Contact Stephen Blood at Stephen.Blood@tucsonaz.gov for the requirements.

2. Building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof (UDC 6.4.4.A). Per tentative plat S02-007, maximum building height allowed is 24'. Ensure that building height does not exceed 24' as measured from design grade to the highest point of the building wall.

3. Sheet A-7 of the submitted plans show an above finish floor elevation of 26'. Sheet A-8 of the submitted plans show an above finish floor elevation of 24'. Clarify the maximum building height on all sheets.

4. Further Zoning review comments may be forthcoming.

If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or 520-837-4951.
10/04/2022 SHASEMA1 ENGINEERING REVIEW Reqs Change 1. Per tentative plat S02-007 general note 14, a grading plan separate from the building plan submittal is required. Ensure proposed and existing contours, drainage flow patterns, cut/fill quantities, site ACS, and adequate spot grading is present. Please follow TSM 9-01 and UDC 5.2 for requirements and more information. Contact Stephen Blood at Stephen.Blood@tucsonaz.gov for any questions.

2. For the above grading plan, provide a Starr Pass Community Approval letter. For clarification, Starr Pass regulates and approves their community grading plans, and the COT requires documentation of their approval letter

3. The retaining wall will require a separate wall permit ("BU" number) for a structural review

Scott Haseman
scott.haseman@tucsonaz.gov
10/04/2022 JCARLTO1 NPPO REVIEW Reqs Change PSDS TRANSMITTAL

ACTIVITY NO. T22PRE0214

ADDRESS/PARCEL: 3170 W TUMAMCO DR/116277640

ZONING: R-1



Per UDC 7.7, a NPPO (Native Plant Preservation Plan) separate from the building plan is required.

This site falls within the following Overlay Zone:

5.2. HILLSIDE DEVELOPMENT ZONE (HDZ)

Add the following notes to the cover sheet:

Revegetation
All cut or fill slopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards:
(1) All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacent site; and,
(2) Revegetation shall be accomplished with the following minimum standards for plants:
(a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and,
(b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD.
(3) A temporary watering system shall be installed until the revegetation materials are established.
3. Slope Stabilization
All slopes steeper than a ratio of three horizontal to one vertical, with the exception of retaining walls, shall be stabilized with properly engineered stone riprapping or sculptured rock as follows:
a. Stone riprapping shall be hand-placed on the slope;
b. The stabilizing material used shall blend with the natural appearance of the site or lot and the surrounding terrain; and,
c. Vegetation retention and revegetation should be used in conjunction with riprapping.
C. Color All exposed exterior walls and roofs of structures, retaining walls, and accessory structures, except satellite dishes, shall be earth tone in color and shall blend with the predominant natural colors found on the lot or parcel. Satellite dishes may be black. White is not permitted.



If you have any questions about this transmittal, please contact Matthew Carlton at Matthew.Carlton@tucsonaz.gov
10/04/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9.

2. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. This requirement can be met with notation or with panel schedule marking "2". Either place the marking at each non GFCI 15 & 20 AMP breakers or remove the partical markings. Many odd circuit numbers are missing the marking on panel A.

3. Energy Certificate: (Mandatory) place near the indoor furnace, in a utility or laundry room, N1101.14. Add notation to plans.
10/05/2022 JVINCEN1 FIRE REVIEW Approved