Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM07075
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
| 09/16/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM07075 4738 E Cecelia St Bathroom and laundry room additions (1st Review) TRANSMITTAL DATE: September 16, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Include the existing driveway in the lot coverage calculation to demonstrate total lot coverage does not exceed 70% of total lot area. Per UDC 6.4.3.B.3.b, vehicular use areas, whether improved or unimproved, are included in the lot coverage calculation. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
| 09/16/2022 | WBERGER1 | NPPO | REVIEW | Passed | |
| 09/27/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM07075 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved Please make corrections and resubmit. Resubmittal shall include a response letter. All code references are to the IRC edition as adopted by Tucson, AR & City of Tucson Amendments to the 2018 IRC unless otherwise noted. Recommend clouding changes to speed up the rereview. 1. Provide note: "The new construction & alterations of the structure, shall be constructed to safely support all loads, including dead loads, live loads, roof loads, flood loads, snow loads, wind loads and seismic loads as prescribed by this code. The construction of buildings and structures in accordance with the provisions of this code shall result in a system that provides a complete load path that meets the requirements for the transfer of loads from their point of origin through the loadresisting elements to the foundation. Buildings and structures constructed as prescribed by this code are deemed to comply with the requirements of this section as per IRC-R301.1. 2. Provide required inspections as per City of Tucson Development Services Department BUILDING REVIEW COMMENTS: Denied Please make corrections and resubmit. Resubmittal shall include a response letter. All code references are to the IRC edition as adopted by Tucson, AR & City of Tucson Amendments to the 2018 IRC unless otherwise noted. Recommend clouding changes to speed up the rereview. 1. Verify Drainage-All drainage shall conform to the requirements of Chapter 32A of the Phoenix City Code as per IRCR401.3. 2. Provide documentation and details of the Roof deck(s) covered with approved roof coverings secured to the building or structure in accordance with the provisions of this chapter. Roof assemblies shall be designed and installed in accordance with this code and the approved manufacturer's instructions such that the roof assembly shall serve to protect the building or structure as per IRC-R903.1. 3. Provide documentation and details of the Flashings on sheet D-1, Detail 7 installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet walls and other penetrations through the roof plane as per IRC-R903.2. 4. Provide documentation and details of the locations Flashings shall be installed at wall and roof intersections, wherever there is a change in roof slope or direction and around roof openings. A flashing shall be installed to divert the water away from where the eave of a sloped roof intersects a vertical sidewall. Where flashing is of metal, the metal shall be corrosion resistant with a thickness of not less than 0.019 inch (No. 26 galvanized sheet) as per IRC-R903.2.1. 5. Provide required inspections as per City of Tucson Development Services Department. MECHANICAL REVIEW COMMENTS: Conditionally Approved Provide required inspections as per City of Tucson Development Services Department. ELECTRICAL REVIEW COMMENTS Conditionally Approved Provide required inspections as per City of Tucson Development Services Department. PLUMBING REVIEW COMMENTS: Conditionally Approved Provide required inspections as per City of Tucson Development Services Department. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |