The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T22CM06999
Parcel: 140550490

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM06999
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/13/2022 SHASEMA1 ENGINEERING REVIEW Passed
09/14/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review


PROJECT:
T22CM06999
5727 E Camino Del Apadrinar - R-1 RCP
New SFR (1st Review)


TRANSMITTAL: September 14, 2022


This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2).

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.

1. The front street perimeter yard setback is not correct and for the main dwelling should be listed as 21’ or the height of the H = The height of the proposed exterior building wall, greater of the two as measured from the from the outside edge of the nearest adjacent travel lane, UDC Article 6.4.5.C.2 and Table 6.4.5.C-1. The street perimeter yard setback to the garage should be listed as A minimum setback of 19 feet from the back of sidewalk UDC Article 6.4.5.C.2.b.(1).

2. The side street perimeter yard setback is not correct and for the main dwelling should be listed as 21’ or the height of the H = The height of the proposed exterior building wall, greater of the two as measured from the from the outside edge of the nearest adjacent travel lane, UDC Article 6.4.5.C.2 and Table 6.4.5.C-1. For this site the setback is measured from back of wedge curb as no parking is allowed along the east side of Avenda Santa Carina.

3. Provide a setback dimension from the proposed SFR to the north property line.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
09/26/2022 JCARLTO1 NPPO REVIEW Passed
09/27/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed