Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM06971
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/12/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
| 09/20/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 09/22/2022 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Completed | |
| 09/23/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM06971 3630 E Fort Lowell Rd – C-1 (1st Review) TRANSMITTAL: September 23, 2022 COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in C-1 Zone (UDC 4.7.20). 1. It is not clear what the proposed use is, code review shows the occupancy to be M (Retail) but sheet A4 calls out dining area and the plans clearly show seating. Zoning considers this a food service use. Provide a vehicle parking space calculation that demonstrates that the mixed use site meets the vehicle parking requirements of UDC Article 7.4.4 If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 09/23/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 09/29/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide listing information and installation instructions for the conveyor toaster. Reference: Section 107.2.1, IBC 2018. 2. Provide general room exhaust for any cooking appliance that does not require the installation of a Type II hood (e.g. toaster, panini press, etc.). The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.1, exception 2 and 507.3, IMC 2018. |
| 09/29/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Provide information to show that the installation of the chocolate fountain complies with the manufacturer's listing requirements (e.g. a water connection is required). Reference: Section 303.2, IPC 2018. 2. Verify that the Pima County Regional Wastewater Reclamation Department will allow the drains from the appliances located in the northeast counter (e.g. dump sink, floor sinks, chocolate fountain, etc.) to bypass the grease interceptor. Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson. 3. Verify that the chocolate fountain does not utilize domestic water as a single-pass coolant. Reference: Section 930, IMC 2018, as amended by the City of Tucson. |
| 09/29/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 10/04/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved |