Permit Number: T22CM06905
Parcel: 122060400

Address:
4337 E LESTER ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM06905
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2022 IMONSHI1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T22CM06905
4337 E Lester St – R-2
Bodega Addition (1st Review)

TRANSMITTAL DATE: 9/09/2022

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This plan at a minimum shall:
a. Show all structures on site. If structures are to be removed, state them as such
b. Shall indicate the zoning of the parcel and all adjacent parcels.
c. Provide a lot coverage calculation

2. Show the height of the structure measured from design grade.

3. Setbacks for the R-2 zone are 6’ or 2/3 * the Height of the structure (whichever is greater). Measured from the structure to the property line. With the proposed setback of 3’ a Design Development Option would be required to reduce the setbacks to the north property line. Contact Mark Castro at Mark.Castro@tucsonaz.gov for more information.



A neighbor waiver can be used to reduce the setbacks for the adjacent western property line. Provide this statement signed by the neighbor to the west on the site plan on the next submittal:

“My Name is ______________ and I am the owner of the property located at ____________. I have reviewed the site plan and I have no objections to structure being located or constructed ______ feet from the property line as depicted on the site plan



Signature:__________________



Date:_______________”



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
09/09/2022 SHASEMA1 ENGINEERING REVIEW Passed
09/12/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set showing 2018 IRC compliance including a wall and foundation detail showing materials, locations, sizing and fastening, electrical, plumbing, heating and cooling.

Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits
10/03/2022 JCARLTO1 NPPO REVIEW Approved