Review Date Reviewer's Name Type of Review Description Status Comments
08/30/2022 SHASEMA1 ENGINEERING REVIEW Passed
09/06/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM06682
Carport
1033 W NAVAJO ST Zoning R-1

TRANSMITTAL DATE:?September 6, 2022


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Clarify if this structure is attached or detached.
1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. This shall in include:
a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements.
b. Zoning of adjacent parcels
c. All Utility lines
d. Property line distances
In the link provided below is a Plot plan grid that can be used.
https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Grid.pdf

2.COMMENT: Provide an elevation drawing, dimension, and label the height of the new structure measured from design grade to top of wall.

3.COMMENT: Clearly show everything on site. Based on current aerial photos there is a porch addition on the southwest portion of the house. Provide permit documentation or include the work in this submittal. (Height, setbacks, square footage) .


4.COMMENT: At this time, I am unable to write DDO comments since I do not have the required information. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). The minimum setback to a street property line is twenty (20) feet or one and one-half the height of the proposed wall (H), measured from the street property line , whichever is greater, up to a maximum of 90 feet. (UDC Section 6.4.5.C.1.a). DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.



If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
09/13/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Zoning approval is required for structure placement on the property.

2. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the as-built addition with necessary alterations for achieving code compliance.

3. The carport roof may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof within 3 feet to the property line or provide a complete wall (fire barrier) with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

4. Provide a complete plan set with 2018 IRC compliant beam, rafter and foundation sizes. Show code compliance or have a structural engineer provide a performance solution.

Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits
09/26/2022 JCARLTO1 NPPO REVIEW Passed