Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM06354
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/18/2022 | VFLORES1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | Unit # needed prior to issuance. You may contact Pima County Addressing Phone #:520-724-9512 Email: addressing@pima.gov |
09/06/2022 | SHASEMA1 | ENGINEERING | REVIEW | Passed | |
09/07/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
09/07/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
09/14/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
09/21/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Denied 1. Sheet A1.0: The exit separation distance is measured incorrectly. Additionally, the measurement provided is not measured between two exits. Provide a correctly measured exit separation distance in accordance with Section 1007.1.1.1. 2. Sheet A1.0: The construction type listed is incomplete. Provide a corrected construction type in accordance with Chapter 6. 3. Sheet A1.0: The occupancy group provided doesn't match the occupancy groups on the egress plan. Provide a corrected occupancy class and a narrative as to the use of the space. 4. Sheet A1.0: Provide clarification about the adjacent tenant to ensure proper tenant separation. 5. Sheet A1.0: There are spaces that have not been counted in the occupant load calculation. Provide a space load calculation in accordance with Section. 1004.3. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner Tucson Fire Department |
09/21/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM06354 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Sheet A1.0: The exit separation distance is measured incorrectly. Additionally, the measurement provided is not measured between two exits. Provide a correctly measured exit separation distance in accordance with Section 1007.1.1.1. 2. Sheet A1.0: The construction type listed is incomplete. Provide a corrected construction type in accordance with Chapter 6. 3. Sheet A1.0: The occupancy group provided doesn't match the occupancy groups on the egress plan. Provide a corrected occupancy class and a narrative as to the use of the space. 4. Sheet A1.0: Provide clarification about the adjacent tenant to ensure proper tenant separation. 5. Sheet A1.0: There are spaces that have not been counted in the occupant load calculation. Provide a space load calculation in accordance with Section. 1004.3. 6. Sheet A2.0: Bathrooms are not permitted to be accessed through storage areas. Provide correctly accessible restrooms in accordance with Section 2902.3.1. MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Denied 1. Please provide a prescriptive path or provide COMcheck calculations for the lighting. All mandatory requirements must be identified on the plans for compliance. Reference IECC Section 505.1 PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
09/21/2022 | VVERA1 | OUT TO CUSTOMER | Completed |