Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM06293
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/17/2022 PAUL CAMARENA ZONING REVIEW Reqs Change FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: T22CM06292, T22CM06293
SFR
830 E 7TH ST Zoning R-2

TRANSMITTAL DATE:?August 17, 2022


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


1.COMMENT: Based on the floor plan from T22-M0060 Unit #1 has four (4) bedrooms and Unit #2 has four (4) bedrooms. Per UDC Table 7.4.4-1 a 4-bedroom unit requires 2.5 for a total of 5 required vehicle parking spaces. Per UDC Article 7.6.4.B the requirements of UDC Article 7.6.4.B landscape requirements apply. And per a Zoning Administrators determination the requirements of UDC Article 7.4.6 vehicle parking requirements apply. Provide a commercial vehicle parking area along with the landscape requirements.


2.COMMENT: Draw dimension and label the setback from the second floor to the property line.

3.COMMENT: Zoning cannot approve the building plans until the DP22-0115 is approved.

If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
08/17/2022 SHASEMA1 ENGINEERING REVIEW Passed Project: T22CM06293
Address: 830 E 7th St Unit 2
This project is within a mapped flood hazard area and requires a Floodplain Use Permit and Elevation Certificate (Note: This is in addition to the FUP required for DP22-0115)

Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp.
Instructions:
1. Is this for a new or existing activity application? – Please select New Application.

2. Submission Type – Select Floodplain Use Permit.

3. Project Name – Enter a name for your project.

4. Type of Permit – Select Commercial or Residential (Residential is for work on single family residences and duplexes.)

5. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided.

6. Description of Work – Enter in Floodplain Use Permit for…and then put a description of the work being done or reference the building permit number associated with this floodplain use permit.

7. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account.

8. Complete the Contractor, Owner and Architect/Engineer sections as applicable.

9. Supporting Documentation Upload – Provide a complete cost estimate for the project unless it is for a new build/separate structure. You may also provide additional documents you think will be helpful.

10. Sign the application and submit.
Contact Loren Makus at Loren.Makus@tucsonaz.gov or Stephen Blood at Stephen.Blood@tucsonaz.gov if you have any questions about the FUP.
08/23/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
09/26/2022 JCARLTO1 NPPO REVIEW Passed