Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM06117
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/11/2022 | SCABRAL1 | ENGINEERING | REVIEW | Passed | |
08/19/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
08/26/2022 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | Activity Number: T22CM06117 - UNIT 283 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. BUILDING REVIEW COMMENTS: Denied Show all new lighting on reflected ceiling plan Show new ceiling tile layout; provide installation details If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
08/29/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
08/29/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
08/30/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
08/30/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
08/30/2022 | ROBERT SHERRY | WATER | REVIEW | Passed | |
09/08/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1 Provide complete power and lighting floor plans showing all branch circuits, lighting controls, and panel designations for all luminaires and electrical devices, mechanical equipment. 2 Show the locations of all new luminaires and correlate identifications of each luminaire with the luminaire schedule. 3 Provide compliance with the 2018 IECC for the lighting. 4 Provide complete panel schedules including load calculations. Indicate if new or existing. 5 If electrical load increases due to additional equipment, provide a complete electrical line diagram and total building load calculations. If there is no electrical load increase, specify this on the electrical plans. 6 Provide for GFI protected receptacles where applicable per NEC 210.8(B). 7 Provide complete compliance with the 2012 Tucson/Pima County Outdoor Lighting Code if applicable. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements, City of Tucson Outdoor Lighting Code (OLC). |