Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM05918
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/11/2022 | SCABRAL1 | ENGINEERING | REVIEW | Passed | |
| 08/15/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 08/18/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/18/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 08/25/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | Ventilation for kitchens in private dwellings requires a minimum of 25 CFM (continuous operation) or 100 CFM (intermittent operation) of mechanical exhaust with no recirculation of air. This may be accomplished with either a kitchen hood or an exhaust fan mounted in the kitchen. (e.g. specify the exhaust flowrate for the kitchen hood). Reference: Table 403.3.2.3, IMC 2018. |
| 08/25/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide a plumbing design for the revised kitchen. Reference: Section 107.2.1, IBC 2018. |
| 08/25/2022 | ROBERT SHERRY | WATER | REVIEW | Passed | |
| 08/30/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. Provide complete electrical power and lighting plans showing all electrical changes and or additional electrical and lighting that complies with the 2017 NEC. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. |
| 09/02/2022 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | Activity Number: T22CM05918 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Sheet 2 1. Provide details of new slab and raised curb for bedroom addition to allow for weep screed for stucco. 2. Provide details for ceiling repairs when wall is being removed, maintain the current joist spacing. 3. What type of door is replacing the window near bdrm #3? If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |