Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05814
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/03/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM05814 4660 S Valley Rd Sunroom (1st review) TRANSMITTAL DATE: August 3, 2022 COMMENTS: The following comments are relative to a Board of Adjustment variance (UDC 3.10.3). This site is in the R-1 zone (UDC 4.7.8). A manufactured home is a permitted use in this zone (Table 4.8-2) and is subject to use-specific standards 4.9.7.B.5-.9. 1. Provide a floor plan of the residence demonstrating compliance with UDC 4.9.7.B.7. Per UDC 4.9.7.B.7, for any single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For all single-family dwellings in the R-1 zone with five or more bedrooms, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. The definition of a bedroom includes any enclosed room, whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms. 2. Sheet 2 of tentative plat S00-014 indicates that the interior building setbacks for all lots is a minimum of three feet. As the proposed construction does not meet the required setbacks as depicted on this Residential Cluster Project's tentative plat, a Board of Adjustment variance is required to reduce the proposed setback. For more information on the variance process, please refer to the following: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. Please contact Mark Castro at Mark.Castro@tucsonaz.gov if you have any questions about the variance process. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
08/03/2022 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
08/04/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | The sunroom may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection. Provide compliance with R302.1 (City of Tucson Amended) by removing the porch roof within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2). |
08/29/2022 | AWARNER1 | NPPO | REVIEW | Approved |