Permit Number: T22CM05684
Parcel: 117021290

Address:
119 E 1ST ST #02

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM05684
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/03/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM05684
119 E 1st St – HR-2
Convert Garage to Sleeping Quarters (1st Review)

TRANSMITTAL: August 3, 2022
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.

As a change in roof design is proposed, flat roof with parapet to pre-fab truss, and no exterior wall heights were provided from design grade to the highest point of the wall, Zoning cannot determine perimeter yard setback requirements. Based on measurements do with our review software the following may apply:

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).
1. Based on a wall height less than 9’-0” the required perimeter yard setback from the proposed sleeping quarters to the north property line is 6’-0”, proposed is 4’-0”.

The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b).
2. Proposed setback to side street Ferro Ave is 5’-0”

Historic review is required for the proposed conversion. Historic review is required and must be approved prior to approval of this building plan. Historic application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf, and is a separate submittal from the building plans submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using Submission Type “Historic Review”.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
08/03/2022 SSHIELD1 ENGINEERING REVIEW Passed
08/13/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM05684

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
See comments under building review.


BUILDING REVIEW COMMENTS:
Denied
No construction plans have been provided.


MECHANICAL REVIEW COMMENTS:
Denied
See comments under building review.


ELECTRICAL REVIEW COMMENTS
Denied
See comments under building review.


PLUMBING REVIEW COMMENTS:
Denied
See comments under building review.


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
08/15/2022 AWARNER1 NPPO REVIEW Approved