Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05669
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM05669 Addition 4910 E 27TH ST Zoning R-2 TRANSMITTAL DATE:?August 2, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Please provide permit documentation for the existing shed southeast portion of the property. If permits are not available, include the information for the shed to this permit. (Size, height setbacks) The setback is the greater of 6ft of 2/3 height, the shed will not be meeting setbacks. A Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. 2.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 08/02/2022 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Instructions: • Is this for a new or existing activity application? – Please select New Application. • Submission Type – Select Floodplain Use Permit. • Project Name – Enter a name for your project. • Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided. • Type of Permit – Select Commercial or Residential (Residential is for work on single family residences and duplexes.) • Complete the Applicant Info. • Complete the Contractor, Owner and Architect/Engineer sections as applicable. • Supporting Documentation Upload – Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful. • Sign the application and submit. • You will be given an activity number for your submittal. Please copy and send this number back to us so we can continue the review. |
| 08/02/2022 | PCAMARE1 | NPPO | REVIEW | Passed | |
| 08/13/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM05669 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied Sheet E-1: Electrical Plan: Indicate the location of required smoke alarms per note 4 and 2018 IRC Section R314.2-4. Provide a carbon monoxide alarm outside the sleeping area as required by 2018 IRC Section R315.2-3, or confirm the lack of any fuel-fired appliances in the home. MECHANICAL REVIEW COMMENTS: Conditionally Approved Mechanical comments: Sheet M-1: It has been indicated that condensate from the FCU will be terminated at a tailpiece fitting on the shower drain pipe inside the wall. Please note that local amendment to 2018 IRC Section M1411.3 provides as follows: Condensate disposal shall be allowed to terminate as follows: 1. Into an approved fixture tailpiece, funnel drain, waste air gap fitting, floor sink, slop sink and laundry tray. 2. At or below grade outside the building in an area capable of absorbing the condensate flow without surface drainage. 3. Over roof drains or gutters or downspouts that connect to drainage pipes, provided they terminate at or above grade in an area capable of absorbing the condensate flow without surface drainage. The allowance for discharging into an approved fixture tailpiece would normally be in an accessible location, and on the building side of the fixture trap. Please consult with local authorities to determine the acceptability of the proposed method, as it will be concealed. ELECTRICAL REVIEW COMMENTS Denied Electrical comments: Sheet E-1: Electrical Plan: Indicate the location of required smoke alarms per note 4 and 2018 IRC Section R314.2-4. Provide a carbon monoxide alarm outside the sleeping area as required by 2018 IRC Section R315.2-3, or confirm the lack of any fuel-fired appliances in the home. PLUMBING REVIEW COMMENTS: Denied Plumbing comments: Sheet P-1: Drainage vent sizing is not indicated at Fixtures P-1 and P-3. Also, please ensure that P-1 is individually vented or re-vented to the 2” VTR. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |