Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2022 IMONSHI1 ZONING REVIEW Reqs Change FROM: Iman Monshizadeh

PDSD Zoning Review Section

PROJECT: T22CM05627 / Room addition

Plot Plan Review (1st Review)

4448 S SUNRISE BLUFF WY / R-1 Zone

TRANSMITTAL DATE: 07/28/2022



Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.



1.COMMENT: A floor plan for the existing residence is required to verify bedroom count in a residential zone. Provide a floor plan showing both the existing house and addition on the next submittal



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
07/28/2022 IMONSHI1 ENGINEERING REVIEW Passed
07/28/2022 IMONSHI1 NPPO REVIEW Passed
08/02/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T22CM05622
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

FLOOR PLANS:

1. Show a floor plan labeling all proposed functions of adjacent rooms and spaces, R106.1.1. Bedrooms have additional requirements from other living spaces.
2. Show if the interior opening into the TV Room is a new opening with new header or a removal of a window or door, R106.1.1.

ELECTRICAL PLANS:

1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12. Show the mini split circuit number.

OUTDOOR LIGHTING CODE

1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.