Permit Number: T22CM05584
Parcel: 134230710

Address:
6641 E COOPER ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM05584
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review Section

PROJECT:
T22CM05584
6641 E Cooper St – R-1
Attached Carport (1st Review)

TRANSMITTAL: July 29, 2022

This site is located in the R-1 zone (UDC 5.10.3). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

COMMENT: Resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. Based on aerial photos and Google Street View there is a carport structure located on the east side of the existing dwelling that is not shown on the plans. Show this structure along with setback dimensions to the east property line. As it does not appear to meet the minimum 6’-0” setback a neighbor’s setback waive may be required. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

2. The 30’-0” dimension from the center of Cooper St to the curb is not correct. Based on Manana Vista final plat the 30’ distance is from center line to property line and the curb location is 15’ south of the property line.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


3. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. As no height dimension from design grade to where the wall meets the eave of the proposed carport Zoning used a measuring function of our review software and it appears that the height is less than 13’-4”. Based on a wall height of less than 13’-4” the required front street perimeter yard setback is 20’-0”, proposed front street perimeter yard setback is 7’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback,
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/29/2022 SSHIELD1 ENGINEERING REVIEW Passed
08/01/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change 1. Provide manufacturer’s calculations and data for pre-engineered trusses dated and wet-sealed by an engineer who is registered in Arizona, or notate the requirement for deferred submittal, R106.1.

2. Show any electrical alterations.
08/26/2022 AWARNER1 NPPO REVIEW Approved