Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05476
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM05476 231 N Country Club Rd Garage (2nd Review) TRANSMITTAL DATE: July 21, 2022 COMMENTS: The following comments are relative to a Board of Adjustment variance (UDC 3.10.3). This site is in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to use-specific standards 4.9.7.B.5-.9. 1. Per UDC 6.6.3.E, the total gross floor area of all accessory structures shall not exceed 50% of the gfa of the principal structure. The proposed construction exceeds 50% of the gfa of the existing principal structure. A detached garage is included with the total gross floor area of all accessory structures per a Zoning Administrator's determination dated May 3, 2006: https://www.tucsonaz.gov/files/pdsd/codes/Sec_3.2.5_Accessory.pdf. The detached accessory garage and workshop may be considered attached to the principal structure is a five-foot-wide roof connection that can support a 20-pound live load is constructed. This roof connection ensures the proposed structure is part of the primary structure, and not subject to the 50% gfa rule. If you propose to attach the proposed construction to the principal structure, Design Development Option (DDO) approval is required to reduce the side and rear perimeter setbacks. The DDO application and its requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. The DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type "Zoning Administration." Please contact Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO application or process. A Board of Adjustment variance is required if the detached garage and workshop are not attached to the principal structure. For more information on the variance process, please refer to the following: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf. Please contact Mark Castro at Mark.Castro@tucsonaz.gov if you have any questions about the variance process. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
| 07/21/2022 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
| 07/21/2022 | WBERGER1 | NPPO | REVIEW | Passed | |
| 08/01/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Approv-Cond | Activity Number: T22CM05476 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditionally Approved No mechanical work was indicated in this submittal ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Conditionally Approved No plumbing work was indicated as part of this submittal If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |