Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM05446
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM05446 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied1. Provide all structural calculations for the installation of the HVAC systems. BUILDING REVIEW COMMENTS: Denied 1. The egress plan provided is incomplete and missing information. Provide a very thorough egress plan, that indicates travel distances, egress signage, exit separation, the location of all equipment and tables, and all other required information. 2. The accessibly plan is incomplete. Clearly show the the location of all tables and equipment and indicate the clear floors spaces for traveling throughout the space. 3. At least 5% of the dining surfaces are required to have mobility features. Provide calculations of the required amount of accessible seating and indicate the locations. Additionally, ensure that surfaces are properly dispersed throughout the structure. Section 226.1 and 226.2 of the 2010 ADAAG. 4. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Classification(s) • For Mixed Occupancy Buildings, state whether the “non-separated” or “separated” option was chosen from Sections 508.3 / 508.4. • Description of Use • Type of Construction • Sprinklers: • Stories • Height • Floor Area • Occupant Load • Justification to exceed allowable area in Table 503 (if applicable) • Justification to exceed allowable height or stories in Table 503 (if applicable) 1. The construction type listed on the cover page is incorrect. Provide a corrected construction type. 2. Provide plumbing fixture requirement calculations. 3. Provide a room finish schedule in accordance with Chapter 8. 4. Provide all accessibility details. 5. Provide an enlarged bathroom plan that shows all dimensions and clear floor spaces. 6. Provide a complete list of adopted and applicable building codes. MECHANICAL REVIEW COMMENTS: Denied 1. Please provide a COMcheck that indicates compliance for new mechanical system and scan that data onto one of the mechanical sheets. This provides evidence the mechanical system is in compliance. 2. Provide a narrative as to what type of cooking will be present and it's relation to the hood requirements. ELECTRICAL REVIEW COMMENTS Denied 1. No egress illumination provided. Provide a sufficient amount of egress illuminations in accordance with Section 1008. PLUMBING REVIEW COMMENTS: Denied 1. Provide the location of required grease interceptors that may be required. Provide al necessary details and sizing calculations. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 08/09/2022 | SCABRAL1 | ENGINEERING | REVIEW | Reqs Change | The CM cannot be approved until the DP22-0181 is approved. |
| 08/09/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/15/2022 | JVINCEN1 | FIRE | REVIEW | Reqs Change | Resolve building comments john.vincent@tucsonaz.gov 5203495581 |
| 08/24/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T22CM05446 – DP22-0181 5602 E Broadway Blvd. – C-1 TI Zeman’s Lounge – (1st Review) TRANSMITTAL: August 24, 2022 This site is located in C-1 Zone (UDC Article 4.7.20) Food Service w/alcoholic beverage service as an accessory use. (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5, 4.9.13.O, 4.9.4.V.1, 3, & 5-9, 4.9.4.C.3, and 4.9.13.O are met. 1. As DP22-0181 has not completed the first review Zoning is not able to compare the building plans to the DP. Once the 1st review of the DP is completed and comments addressed Zoning will review the building plans for compliance with the DP. Additional comments maybe forth coming. Zoning cannot approve the building plans until the DP is approved by all review agencies. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 08/24/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/24/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |