Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T22CM05440
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 08/03/2022 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the electrical plan review comments and provide a written response. 1 Show electrical branch circuits, disconnecting means, for the kitchen hood, water heater, kitchen exhaust fan on the electrical power plans. Ref; 2018 IBC sec 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. 2012 Tucson/Pima County Outdoor Lighting Code (OLC) |
| 08/04/2022 | IMONSHI1 | ENGINEERING | REVIEW | Passed | |
| 08/04/2022 | IMONSHI1 | ZONING | REVIEW | Approved | |
| 08/04/2022 | IMONSHI1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 08/16/2022 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Revise the installation note for the grease exhaust fan to call for a minimum termination height of 40" above the roof. Reference: Section 506.3.13.1, IMC 2018. 2. Provide structural calculations and details to show that the Type I hood is supported from the building structure in accordance with Section 507.2.4, IMC 2018 (the hood hanging weight plus the weight of personnel working in or on the hood). Reference: Section 302.1, IMC 2018. 3. The mechanical plan shows an existing high velocity diffuser for the HVAC supply air system in close proximity to the face of the Type I hood. Verify that the location and type of air outlet complies with the hood manufacturer's installation instructions and does not reduce the effectiveness of the exhaust system. Reference: Sections 304.1 and 508.1, IMC 2018. 4. Verify that the evaporative cooling section of the makeup air unit is equipped with a recirculating water system. Reference: Section 928.2, IMC 2018 and ARS Title 45, Chapter 1, Article 12. See text at: (http://www.azleg.gov/viewdocument/?docName=http://www.azleg.gov/ars/45/00313.htm). |
| 08/16/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Verify that the downstream vent for the hydromechanical grease interceptor rises vertically to at least 6" above the flood rim of the grease interceptor prior to running horizontally. Reference: Section 905.4, IPC 2018 2. The specified hydromechanical grease interceptor (Canplas) requires the installation of a vented, external flow control device. Show how this device is to be installed. Reference: Sections 303.2 and 1003.3.5.2, IPC 2018. |
| 08/16/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/19/2022 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Completed |