Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05388
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/21/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Clarify the application description: Garage Addition or Renovate Shop into Guesthouse with Porch. Provide a complete plan set showing 2018 IRC compliance. |
| 08/02/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM05388 ADU 2124 E KLEINDALE RD Zoning RX-2 TRANSMITTAL DATE:?August 2, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Please clarify if this structure is to be considered an ADU ADU Comments Provide a parking space. In addition to parking required for the principal use , one parking space shall be provided for the accessory dwelling unit . The parking requirement may be satisfied with available on-street parking or waived if the site is within ΒΌ mile walking distance of a transit stop or an enhanced bike route as listed in the Bike Boulevard Master Plan. Parking provided is exempt from Section 7.6.4, Landscape Standards. On sites where the principal structure is one story, accessory dwelling units shall not exceed 12 feet in height. On sites where the principal structure is two stories or greater, the height of the accessory dwelling unit may be equal to the height of the principal structure . For lots less than 6,500 square feet in size, the accessory dwelling unit is limited to 650 square feet of gross floor area . For lots equal to or greater than 6,500 square feet, the accessory dwelling unit is limited to 10% of the lot size, not to exceed 1,000 square feet of gross floor area . Accessory structures , except for accessory dwelling units , shall not exceed 12 feet in height, unless attached to a principal structure . If attached to the principal structure , maximum height permitted shall be the same as for the principal structure ; and, 2.COMMENT: Clearly show everything on site. Based on current aerial photos there storage on the west side of the property Provide permit documentation or include the information on this permit ( Size, height, setback distance) https://gis.pima.gov/pictometry/ipa/IPAfullnet/llviewer.aspx?lat=32.2683&lon=-110.9398 If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 08/02/2022 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 08/02/2022 | PCAMARE1 | NPPO | REVIEW | Passed |