Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM05339
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM05339 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Sheet SD1: The proper amount of engineered fill has not been provided in relation to the soils report. Provide the proper amount of engineered fill. BUILDING REVIEW COMMENTS: Denied 1. The occupant load is calculated incorrectly. Section 303.1.1 has been applied incorrectly. However, for this particular case it would not affect the outcome. Use the correct occupant load factor for business in accordance with Table 1004.5. 2. No egress plan provided. Provide a thorough egress plan. 3. Sheet A2.0: The south wall of the structure would require to be rated in accordance with Section 705.3. If the other building is existing ensure that Section 705.3 is followed specifically and correlate any other requirements to the proposed structure, focusing on protected openings. MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 07/29/2022 | WBERGER1 | ENGINEERING | REVIEW | Reqs Change | See Zoning comments |
| 07/29/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM05339 1855 E Fort Lowell Rd New Dutch Bros (1st Review) TRANSMITTAL DATE: July 29, 2022 This site is in the C-1 zone (UDC 4.7.20). Food Service: Excluding Soup Kitchens is a permitted use in this zone (Table 4.8-4) and is subject to use-specific standards 4.9.4.M.1 & .5 and 4.9.13.O. 1. Per UDC 3.3.3.G.2.a, as you are proposing new non-residential development, an approved Development Package (DP) is required. The DP is a separate submittal and shall be submitted at https://docs.tucsonaz.gov/Forms/tucsonpermitapp, using Submission Type "Site Review." Zoning acknowledges that DP20-0060 has been submitted for this project; however, the one year expiration date for resubmittal passed March 17, 2021. A new DP is required. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov. |
| 07/29/2022 | WBERGER1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 08/10/2022 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 08/15/2022 | JVINCEN1 | FIRE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/15/2022 | VVERA1 | OUT TO CUSTOMER | Completed |