Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05317
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/13/2022 | GSLEIGH1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Reqs Change | Each dwelling requires unique address, units can be added through Pima County Addressing. |
| 07/20/2022 | PAUL CAMARENA | ZONING | REVIEW | Reqs Change | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM05317 ADU 1700 E GRANT RD Zoning NR-1 TRANSMITTAL DATE:? July 20, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Draw dimension and label the height of the new structure measured from design grade to top of wall. Please provide an accurate scale on the elevation drawings. 2.COMMENT: After reviewing the aerials it appears that the existing storage shed is unpermitted. Please provide permit documentation or add shed information to this permit (Height, Setback information, and square footage.) Please consider moving the storage to avoid doing a design Development Option. The streetside setback is 10 ft. 3.COMMENT: This site is located in the NR-1 zone (UDC 5.10.3). NPZ review for compliance with the neighborhood design manual is required. Please submit an NPZ application review after all other zoning review section comments are addressed and the exterior design is finalized. Zoning cannot approve until the NPZ review has been approved. Please contact Specialdistricts@tucsonaz.gov. In the link provided below is the application for the Special districts Application: https://www.tucsonaz.gov/files/integrated-planning/Special_Districts_Application_Revised_5-23-22_fillable_0.pdf The following comment are regarding the ADU 4.COMMENT: Please provide a parking for the ADU “In addition to parking required for the principal use , one parking space shall be provided for the accessory dwelling unit . The parking requirement may be satisfied with available on-street parking or waived if the site is within ¼ mile walking distance of a transit stop or an enhanced bike route as listed in the Bike Boulevard Master Plan.” Provide a note that the structure will be constructed with cool roof technology “If the accessory dwelling unit is built as a new structure it must be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code” Provide a note “For lots less than 6,500 square feet in size, the accessory dwelling unit is limited to 650 square feet of gross floor area . For lots equal to or greater than 6,500 square feet, the accessory dwelling unit is limited to 10% of the lot size, not to exceed 1,000 square feet of gross floor area .” If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
| 07/20/2022 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 07/25/2022 | PCAMARE1 | NPPO | REVIEW | Passed | |
| 07/25/2022 | PCAMARE1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |