Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05272
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/19/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM05283 4218 E Irving Cl Additions and enclosures to residence (1st Review) TRANSMITTAL DATE: July 19, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Provide a lot coverage calculation on the next submission. Lot coverage includes the area of the site occupied by buildings, outdoor storage areas, and vehicular use areas (improved and unimproved). 2. Indicate the maximum structure height on the elevations provided, measured from design grade. 3. Per UDC 6.4.5.C.1.a, within established areas, the minimum required front street perimeter yard is 20 feet or one and one-half the height of the proposed wall, measured from the street property lines, whichever is greater. Demonstrate the minimum required front street setback is being met. 4. Demonstrate compliance with UDC 4.9.7.B.7. As you are proposing five bedrooms, three parking spaces are required. For all single-family family dwellings in the R-1 zone with five or more bedrooms, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used. 5. There are detached accessory structures along the rear perimeter wall that do not appear to have permit approval. Either provide permit approval documentation or include them within this permit's scope of work. Demonstrate that these accessory structures are also not located within the five-foot-wide utility easement. 6. Per UDC 6.6.2.D, If these accessory structures are not meeting the minimum required setbacks (and are not within the utility easement) the accessory structure(s) may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My name is _________ and I am the owner of the property located at _________. I have reviewed the site plan and I have no objection to the structure being located or constructed __ feet from the property line as depicted on the site plan. Signature: _________ Date: _________ 7. Further Zoning Review comments may be forthcoming. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or 520-837-4951. |
| 07/19/2022 | WBERGER1 | ENGINEERING | REVIEW | Passed | |
| 07/29/2022 | AWARNER1 | NPPO | REVIEW | Approved | |
| 07/30/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM05272 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Provide the designed live and dead loads for the structural design of the additions as well as a basic designed wind speed of 115 mph and a seismic category B. 2018 IRC table R301.2(1) as amended. BUILDING REVIEW COMMENTS: Denied 1. Provide a landing outside of door 7 that is a minimum of 36” deep in the direction of travel and at least as wide as the door it serves. 2018 IRC R311.3. MECHANICAL REVIEW COMMENTS: Denied 1. Provide a mechanical plan for the new additions and indicate if they will be tied to an existing system that is large enough to except the new load or if new unit(s) will need to be installed. 2. Note on the drawings that all bath fans will be exhausted directly to the exterior. 2018 IRC M1505.2. ELECTRICAL REVIEW COMMENTS Denied 1. Indicate a light outside of the new door 7 on the plans. 2017 NEC 210.70. 2. Indicate the switching for the new foyer lighting fixtures on the drawings, some of the lines appear to be missing. 3. Indicate the location of an existing exterior outlet at the rear of the house or indicate new one will be provided. 2017 NEC 210.52. 4. Indicate the location of all some detectors in the house including the existing bedrooms. Smoke detectors shall be installed in each sleeping room, and outside of each sleeping room in the immediate vicinity of the bedroom. 2018 IRC R314.2. All smoke detectors shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. 5. Indicate the location of all carbon monoxide detectors on the plan including for the existing bedrooms. Carbon monoxide device shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined. PLUMBING REVIEW COMMENTS: Denied 1. Update plumbing plan note 13 to indicate the showerheads and faucets to not exceed 2.5 gallons a minute. Ordinance 7178. 2. Indicate if the new fixtures will be tied to an existing water heater or if a new water heater will be provided. Show the location of the water heater on the plans. 3. Indicate where the new plumbing fixtures will be tied into the existing water lines, only the sewer was shown. 4. Note on the drawings that all plumbing drain, waste and vent systems shall be tested for leaks in accordance with the 2018 IRC P2503.5 prior to concealing. 5. The plumbing plans appear to indicate a hose bib in the existing wall where the new master bedroom addition is located. Clarify it this is an existing hose bib that is being relocated to the front of the house 6. Provide a gas piping diagram for any new gas appliances on the drawing including water heaters and HVAC units or indicate no gas piping is required as part of this submittal. If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |