Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM05271
Parcel: 129023010

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM05271
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2022 WBERGER1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Wyatt Berger
Planner

PROJECT: T22CM05271
2625 E Croyden St
Additions and enclosures to residence (1st Review)

TRANSMITTAL DATE: July 19, 2022

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11).

1. Provide a lot coverage calculation for the area of the site covered by buildings, outdoor storage areas, and vehicular use areas (both improved and unimproved).

2. Show the five-foot-wide overhead easement at the rear of the property.

3. Provide a floor plan of the entire residence to demonstrate compliance with UDC 4.9.7.B.7. For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all single-family family dwellings in the R-1 zone with five or more bedrooms, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.

4. Per UDC 6.4.5.C.1.a, within established areas, the minimum required front street perimeter yard is 20 feet or one and one-half the height of the proposed wall, measured from the street property lines, whichever is greater. Based on a wall height of approximately 14'-0", the minimum required front street setback is 21'-0"; proposed is 18'-0."

Per UDC Table 6.3-2.A, the minimum required interior setbacks are six feet or 2/3 the height of the proposed wall, whichever is greater. Based on a wall height of 10'-8", the minimum required side yard setback measured to the west lot line is 7'-1"; proposed is 6'-2".

A DDO must be submitted and approved to reduce the required setbacks. The DDO application and its requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. The DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type "Zoning Administration." Please contact Mark Castro at Mark.Castro@tucsonaz.gov if you have questions about the DDO application or process.

If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or 520-837-4951.
07/19/2022 WBERGER1 ENGINEERING REVIEW Passed
07/19/2022 WBERGER1 NPPO REVIEW Passed
07/30/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM05271


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Update the general framing design notes on sheet A2.0 to indicate a basic designed wind speed of 115 mph and a seismic category B. 2018 IRC table R301.2(1) as amended.
2. Indicate how the new foundation will be tied into the existing such as with rebars or other suitable method.


BUILDING REVIEW COMMENTS:
Approved


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Denied
1. Indicate a light outside of the new bedroom door to the existing patio. 2017 NEC 210.70.
2. Note on the drawings that the new can lighting installed in the ceiling will be IC rated and sealed for energy efficiency requirements. 2017 NEC 410.66.
3. Note that a minimum of 90% of all lighting fixtures in the dwelling will contain high-efficacy lamps. 2018 IECC R404.1.
4. Note that all new or replaced 15- and 20-amp outlets shall be tamper proof type. 2017 NEC 210.52.
5. Indicate smoke detectors will be installed in the existing house. Smoke detectors shall be installed in each sleeping room, and outside of each sleeping room in the immediate vicinity of the bedroom. 2018 IRC R314.2. All smoke detectors shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4.
6. Indicate carbon monoxide devices will be instead in the existing ho use. Carbon monoxide device shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined.


PLUMBING REVIEW COMMENTS:
Conditionally Approved
No plumbing work has been included in this submittal


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov