Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T22CM05249
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/24/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: PDSD Zoning Review Section PROJECT: T22CM05249 1627 N MOUNTAIN VIEW AVE - R-1 Master Bedroom Addition (2nd Review) TRANSMITTAL DATE: August 24, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. This comment was not fully addressed. Heights and setback dimensions were not provided. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). If either of the sheds shown on the plan do not meet perimeter yard setbacks at a minimum a neighbor’s setback waiver will be required. Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ COMMENT: Clearly show everything on site. Based on current aerial photos there ar three possible unpermitted shed on the rear portion of the property. Provide permit documentation for the sheds or include them in this submittal. (Square footage, height and building setbacks) Additional comments may be forth coming. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
| 08/29/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Completed | Activity Number: T22CM05249 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved PLUMBING REVIEW COMMENTS: Conditionally Approved No plumbing work has been indicated as part of this submittal If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |