Permit Number: T22CM05198
Parcel: 128120820

Address:
4901 E 17TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM05198
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/18/2022 STEVE SHIELDS ZONING REVIEW Approved
07/18/2022 SSHIELD1 ENGINEERING REVIEW Passed
07/29/2022 AWARNER1 NPPO REVIEW Approved
08/05/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Approv-Cond Activity Number: T22CM05198
GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved


BUILDING REVIEW COMMENTS:
Approved


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Conditionally Approved
1. A minimum of 90% of all lighting fixtures in the dwelling will contain high-efficacy lamps. 2018 IECC R404.1


PLUMBING REVIEW COMMENTS:
Conditionally Approved
1. Showers shall be provided with pressure balance, thermostatic mixing, or a combination valve with a high limit stop in accordance with ASSE 1016. The high limit stop shall be set to limit the maximum water temperature setting to 120 degrees. 2018 IRC P2708.4


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov