Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM05079
Parcel: 14118001H

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM05079
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2022 VFLORES1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Reqs Change Please provide suite number. If not sure you may contact Pima County Addressing Phone #:520-724-9512 Email: addressing@pima.gov
07/21/2022 WBERGER1 ENGINEERING REVIEW Passed
07/21/2022 WBERGER1 ZONING REVIEW Approved
07/21/2022 WBERGER1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
07/22/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM05079


GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Conditionally Approved
No structural modifications are included in this submittal


BUILDING REVIEW COMMENTS:
Denied
1. The floor plan on sheet A1.0 indicates the doors from the closet 125 and utility room 124 will swing into the egress corridor 136. Indicate the required width of the clear egress path and the door swing projections for corridor 136 on the drawings. Doors in any position may not reduce the required width of the egress path by more than one half. 2018 IBC 1005.7.1.
2. Provide an elevation or note the required accessibility heights and clearances for the high low drinking fountain located in the lounge 103. (It appears that the furniture layout may interfere with the required clear space in front of the unit.)


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Denied
1. Update the COM check on sheet E4.01 to indicate compliance with the 2018 IECC, not the 2012. Update the fixture counts so it matches the lighting fixture schedule on sheet E2.01.
2. Show the location of the existing emergency light outside of the egress doors or indicate a new one will be provided. 2018 IBC 1008.3.2.
3. Clarify the location for the switching or sensors for the lounge 103, reception 102, MA-1 113 and MA-2 122.
4. Clarify the location of the “night lighting” in the open areas. It is understood that the emergency lighting with battery backup are integrated into lighting fixtures A1, B1 and C1 however it is not known if these will provide lighting the hallway under normal conditions (not emergency). It appears these lights are switched and can be turned off. 2018 IBC 1008.2


PLUMBING REVIEW COMMENTS:
Approved


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
08/04/2022 ROBERT SHERRY WATER REVIEW Reqs Change Provide the size of the water meter serving this suite, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018.
08/25/2022 JVINCEN1 FIRE REVIEW Reqs Change Resolve building comments.
john.vincent@tucsonaz.gov
5203495581

Final Status

Task End Date Reviewer's Name Type of Review Description
08/25/2022 VVERA1 OUT TO CUSTOMER Completed