Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM05065
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/13/2022 | WBERGER1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Wyatt Berger Planner PROJECT: T22CM05065 7576 S Danforth Av Remove small attached patio cover and install larger patio cover (1st Review) TRANSMITTAL DATE: July 13, 2022 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Provide a site plan that meets the residential plot plan requirements found at https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. At a minimum, the site plan shall: a. Show the square footage of the lot, existing dwelling, accessory structures, additions, and total under roof area. b. Provide a lot coverage calculation. Lot coverage includes the area of the site occupied by buildings, outdoor storage areas and vehicular use areas. c. Provide the height of the exterior walls of the new building addition. d. Show the setbacks measured from the proposed construction to the property lines. e. Show the six-foot-wide public utility easement at the front street lot line and show the one-foot-wide no access easement at the rear lot line. 2. Per UDC Table 6.3.2-A, the required side and rear perimeter yard setbacks are the greater of six feet or 2/3 the height of the proposed exterior building wall. The accessory shed on the site plan does not appear to meet the required east lot line setback. Per UDC 6.6.2.D, an accessory structure that exceeds the allowable height of wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My name is _________ and I am the owner of the property located at _________. I have reviewed the site plan and I have no objection to the structure being located or constructed __ feet from the property line as depicted on the site plan. Signature: _________ Date: _________ 3. Combine all sheets into one PDF file in your next submission. If you have any questions about this transmittal, please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or 520-837-4951. |
| 07/13/2022 | WBERGER1 | NPPO | REVIEW | Passed | |
| 07/14/2022 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 07/25/2022 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed |