Permit Number: T22CM05038
Parcel: 127032310

Review Status: Completed

Review Details: OTHER

Permit Number - T22CM05038
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/05/2022 GSLEIGH1 OIP REVIEW Completed Gas line undersized. Diagram requires length and diameters between every fitting, the combined 24' length off the tee must be broken down into different measurements. It's likely the diagram is innacurate, as the house line from the meter is almost always greater than 1/2" diameter.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/05/2022 NGARCIA3 OUT TO CUSTOMER Completed