Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T22CM05033
Parcel: Unknown

Address:
1102 E 36TH ST

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM05033
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/23/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM05033

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Provide Structural Calculations
2. Provide Structural details complete with steel framing member sizes and connector sizes marked on the plan


BUILDING REVIEW COMMENTS:
Denied
Cover sheet – Provide list of applicable building codes with City of Tucson amendments.
Cover sheet – Provide vicinity and location maps.
Cover sheet – Provide project description. How many new canopies (36?) and how much of total area (SF)? Is there any electrical work? Lightning protection system? Gutter system per 2018 IPC?
Cover sheet/Sheet 1 of 2 - Provide code information such as total canopy area (SF), occupancy classification (U?), canopy height (ft), canopy construction type (ll-B?) per 2018 IBC. What is the total area of the new canopies? How many total canopies? 36?
Floor plan – Provide typical canopy floor plan showing surface parking stripes and column/foundation locations.
Reflected ceiling plan – Provide typical reflected ceiling plan showing ceiling height and material finish. Lighting if any.
Exterior elevations – Provide typical exterior elevations. How are canopies identified? Show identification labels for inspections.
Roof plan – Provide typical roof plan showing drain method and roof materials per 2018 IBC.
Carport Identifier sheet – Width and length (8’-6”x18’) does not match canopy size shown in A/page 1 of 2. Provide typical canopy floor plan, etc. to clarify this.
Sheet A1.01 – Provide total canopy area (SF) sum of label A through JJ highlighted yellow to define the scope.
Sheet A1.01 - 9 van ADA parking is stated in A1.01. Show their locations.
Sheet 1 of 2 – Canopy section B shows canopy ceiling height of 7’-0” to 8’-2” define ceiling height for canopies A through JJ. Van parking, where provided, is addressed in 2018 IBC Sections 406.2.3 and 1106. The clear height at canopies regulated under Section 406.7.2 is 13 feet 6 inches. Show VAN locations in site plan and schedule (HC).


MECHANICAL REVIEW COMMENTS:
N/A

ELECTRICAL REVIEW COMMENTS
Approved

PLUMBING REVIEW COMMENTS:
N/A

If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
07/26/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM05033 – DP21-0078
1102 E 36th St – PAD-15
Covered Parking Structures (1st Review)

TRANSMITTAL: July 26, 2022
This site is located in PAD-5, Multi-Family is an allowed use in the PAD.

1. The provided development package (DP) sheets shall be the approved stamped plans.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/26/2022 SSHIELD1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
08/02/2022 SSHIELD1 ENGINEERING REVIEW Passed
08/03/2022 ROBERT SHERRY WATER REVIEW Completed
09/06/2022 JVINCEN1 FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/06/2022 VVERA1 OUT TO CUSTOMER Completed