07/25/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM05032

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Indicate in the drawings the designed live and dead load for the new addition. Indicate that the structure was designed for a basic wind speed of 115 mph and a seismic design category B. 2018 IRC table R301.2(1) as amended.
2. Indicate that the soil under the slab and around the footings will be treated for termites prior to the pouring of the concrete. 2018 IRC R318.


BUILDING REVIEW COMMENTS:
Denied
1. Indicate the energy requirements on the plans for the new windows. Windows are required to have a minimum U factor of .40 and a SHGC of .25. 2018 IECC table R402.1.2.
2. Indicate the door from the house to the garage will have a minimum of a 20-minute fire rating and be equipped with a self-closing device. 2018 IRC R302.5.1.
3. Indicate that the dwelling will be separated from the attached garage by not less than ½” gypsum board or equivalent installed on the garage side of the wall or ceiling. This will include the separation of any attic spaces. 218 IRC table R302.6.


MECHANICAL REVIEW COMMENTS:
Approved


ELECTRICAL REVIEW COMMENTS
Denied
1. Update note 10 on sheet E101 to indicate smoke detectors will be installed in the existing house. Smoke detectors shall be installed in each sleeping room, outside of each sleeping room in the immediate vicinity of the bedrooms. 2018 IRC R314.2. All smoke detectors shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4.
2. Update note 15 on sheet E101 to indicate carbon monoxide detectors will be installed in the existing house. Carbon monoxide detectors shall be installed outside of each sleeping area in the immediate vicinity of the bedrooms. 2018 IRC R315.3. Carbon monoxide devices shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined.