Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM04865
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 07/18/2022 | SSHIELD1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved | |
| 07/18/2022 | STEVE SHIELDS | ZONING | REVIEW | Passed | |
| 08/08/2022 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 08/19/2022 | WILDAN | BUILDING-COMMERCIAL | REVIEW | Reqs Change | Activity Number: T22CM04865 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Sheet G1.0; Accessible ingress is not part of the scope of the review. DMA Sheet G1.0; Scope of this review is limited based upon the information provided. DMA Sheet G1.0, 2010 ADA, 2009 A117.1. List codes plans have been in conformance with. DMA Sheet G1.0; Identify any and/or all Special Inspections required, example; Welding, post installed anchors, etc... and Deferred items. DMA Sheet G1.0; Plans do not provide any building code data. This limits the scope of the review. DMA Sheet G2.0, 2010 ADA Section 405; Alteration to ramp requires compliance with this code and section. DMA Sheet G2.0; The additional occupant load calcs, travel distance and design from the pool served by this exit and the adjacent exit gate has not been provided and are not part of this review. DMA Sheet G2.0, 2018 IBC Section 1028.5 Exc 4; Confirm safe and unobstructed path of travel from the building in accordance with the condition 4 of the Exception. DMA Sheet G2.0, 2018 IBC Section 1009.1 (consistent with 2003 IBC as referenced in the 2010 ADA); One accessible means of egress shall be provided, where two means of egress from the accessible portion is required than two means of egress are required. DMA Sheet G2.0, 2018 IBC Section 1009.2; Continuity of the accessible means of egress is required and shall be continuous to a public way and must consist of one or more of the 10 items listed in this section. DMA Sheet G2.0, 2018 IBC Section 1017 Table 1017.2; Plans do not provide a complete Building Data analysis, verify compliance with this table. DMA Sheet X1.1; This is not consistent with note on Sheet G2.0 that identifies ramp as being replaced which would be considered an alteration. DMA If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/19/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |