Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T22CM04862
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/09/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM04862 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Provide a separate demolition plan or show the removed wall(s) on the floor plan sheet A.1. The fire protection plan sheet FP2.0 indicates there was a demising wall in the carpentry area that was removed. 2. Coordinate the exiting plan sheet A.2 with the reflected ceiling and electrical plan for the locations of the exit signage and common paths of egress. The plans do not match. 3. Office 125 is indicated on the exiting plan sheet EP.1 as part of the required egress. Indicate the clear discernible path through the office to be maintained at all times and note that the door will not have locking hardware. 2018 IBC 1016.2. MECHANICAL REVIEW COMMENTS: Denied 1. Clarify if the existing painting and carpentry construction areas have existing exhaust fans. An exhaust system is required in areas where machines or equipment throw off dust or particles, odors, fumes, spray, gas, or smoke in such quantities so as to be irritation or injurious to health and safety. 2018 IMC 502.1. The electrical power plan E.2 indicates new electrical for air filter units in the carpentry area only, but no other information is provided to determine if they will be sufficient to provide a safe working environment. ELECTRICAL REVIEW COMMENTS Denied 1. Show the location of all existing or new night lighting, emergency lighting and exit signage on the reflected celling and electrical plans. 2. Include the location of the existing emergency light outside of the egress doors per 2018 IBC 1008.3.2, or show a new one will be installed. PLUMBING REVIEW COMMENTS: Approved If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
| 07/15/2022 | IMONSHI1 | ENGINEERING | REVIEW | Passed | |
| 07/15/2022 | IMONSHI1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Reqs Change | Once all comments are addressed, impact fees will be assessed. |
| 07/15/2022 | IMONSHI1 | ZONING | REVIEW | Reqs Change | FROM: Iman Monshizadeh PDSD Zoning Review Section PROJECT: T22CM04862 / TI Plot Plan Review (1st Review) 6363 S Country Club Rd / I-1 Zone TRANSMITTAL DATE: 07/15/2022 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: mezzanine addition counts as an addition of square footage to a commercial use and therefor requires an approved development package for the site. A Development package is a separate submittal and must be submitted and approved prior to the approval of the TI. Information on the development package can be found here: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf Development Package application can be found here: https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp |
| 07/21/2022 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 07/25/2022 | ROBERT SHERRY | WATER | REVIEW | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/25/2022 | NGARCIA3 | OUT TO CUSTOMER | Completed |