Permit Number: T22CM04862
Parcel: 14029037D

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T22CM04862
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2022 SAFEBUILT 2ND PARTY REVIEW REVIEW Reqs Change Activity Number: T22CM04862

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Approved

BUILDING REVIEW COMMENTS:
Denied
1. Provide a separate demolition plan or show the removed wall(s) on the floor plan sheet A.1. The fire protection plan sheet FP2.0 indicates there was a demising wall in the carpentry area that was removed.
2. Coordinate the exiting plan sheet A.2 with the reflected ceiling and electrical plan for the locations of the exit signage and common paths of egress. The plans do not match.
3. Office 125 is indicated on the exiting plan sheet EP.1 as part of the required egress. Indicate the clear discernible path through the office to be maintained at all times and note that the door will not have locking hardware. 2018 IBC 1016.2.


MECHANICAL REVIEW COMMENTS:
Denied
1. Clarify if the existing painting and carpentry construction areas have existing exhaust fans. An exhaust system is required in areas where machines or equipment throw off dust or particles, odors, fumes, spray, gas, or smoke in such quantities so as to be irritation or injurious to health and safety. 2018 IMC 502.1. The electrical power plan E.2 indicates new electrical for air filter units in the carpentry area only, but no other information is provided to determine if they will be sufficient to provide a safe working environment.


ELECTRICAL REVIEW COMMENTS
Denied
1. Show the location of all existing or new night lighting, emergency lighting and exit signage on the reflected celling and electrical plans.
2. Include the location of the existing emergency light outside of the egress doors per 2018 IBC 1008.3.2, or show a new one will be installed.


PLUMBING REVIEW COMMENTS:
Approved



If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
07/15/2022 IMONSHI1 ENGINEERING REVIEW Passed
07/15/2022 IMONSHI1 ZONING REVIEW Reqs Change FROM: Iman Monshizadeh

PDSD Zoning Review Section

PROJECT: T22CM04862 / TI

Plot Plan Review (1st Review)

6363 S Country Club Rd / I-1 Zone

TRANSMITTAL DATE: 07/15/2022



Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.



1.COMMENT: mezzanine addition counts as an addition of square footage to a commercial use and therefor requires an approved development package for the site.

A Development package is a separate submittal and must be submitted and approved prior to the approval of the TI.

Information on the development package can be found here: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

Development Package application can be found here:

https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf





For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp
07/15/2022 IMONSHI1 COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Reqs Change Once all comments are addressed, impact fees will be assessed.
07/21/2022 JPEELDA1 FIRE REVIEW Approved
07/25/2022 ROBERT SHERRY WATER REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
07/25/2022 NGARCIA3 OUT TO CUSTOMER Completed