Permit Number: T22CM04640
Parcel: 133070710

Address:
8602 E RANCHO CI

Review Status: Completed

Review Details: OTHER

Permit Number - T22CM04640
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/21/2022 GSLEIGH1 OIP REVIEW Reqs Change Total developed length per diagram is 72'. 1" gas line for this length is insufficient for gas loads as drawn, providing 220k BTU's while 230k are needed. Line to gas pack is underized.

Review completed in accordance with IRC 2018, table G2413.4(1)

Final Status

Task End Date Reviewer's Name Type of Review Description
06/21/2022 VVERA1 OUT TO CUSTOMER Completed