Permit Number: T22CM04632
Parcel: 125091950

Address:
3056 E 8TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T22CM04632
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/05/2022 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T22CM04632
2245 E 8th St - R-1
Convert Existing Garage to Rec Room (1st Review)

TRANSMITTAL: July 5, 2022

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9

1. The addressed, 3056 E 8th St, provided on the application is not correct. Provide a new application with your next submission that has the correct addressed.

2. The lot coverage calculation is not correct. Review UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, and provide a correct lot coverage calculation.

3. Show all utilities on the plot plan.

4. Provide perimeter yard setback dimensions from the garage to the north and west property line. As you are converting the garage from non-habitable space to habitable space if the garage setback is less than 6’-0” or 2/3 the height of the exterior wall, greater of the two as measured from design grade to the highest point of the wall, a neighbor setback waiver is required. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

5. The proposed floor plan for the garage conversion is considered a dwelling unit, double bowl sink and full-size refrigerator. For this conversion not to count as a dwelling unit the double bowl sink will need to be replaced with a single bowl bar type sink, and the refrigerator will need to be shown as an under-counter refrigerator. If the floor plan is to remain as shown impact fees of approximately $2748.00 will apply.

6. Provide full floor plans for both “A” and “B” on the plan so that vehicle parking requirements and the total number of dwelling units can be verified.

Once the comments above have been addressed additional comments maybe forth coming.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/05/2022 SSHIELD1 ENGINEERING REVIEW Passed
07/07/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide plans with the same address as appears on the application.
07/15/2022 AWARNER1 NPPO REVIEW Approved