Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T22CM04626
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2022 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 07/01/2022 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 07/01/2022 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 07/22/2022 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T22CM04626 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Approved BUILDING REVIEW COMMENTS: Denied 1. Note on the cover sheet T-1 that all work will be done in accordance with the adopted codes and ordinances of the City of Tucson. (Not just the IRC) 2. Provide dimensions on the floor plan indicating the size of the new mud room. Habitable room shall be a minimum of 70 sf and not be less than 7’ in any direction. 2018 IRC R304. MECHANICAL REVIEW COMMENTS: Denied 1. Provide information on how the new mud room and converted laundry area will be vented and heated, no mechanical information was included with this submittal. 2018 IRC R303. ELECTRICAL REVIEW COMMENTS Denied 1. Show the existing electrical receptacles, switch, and lighting in the laundry room on the drawings. 2. Note that all new outlets installed in bedrooms, living rooms, family rooms, dens, hallways and similar areas will be ARC fault protected. 2017 NEC 210.12 3. Note that all new or replaced 15- and 20-amp outlets shall be tamper proof type. 2017 NEC 210.52. 4. Update the smoke detector note on sheet A2. Smoke detectors shall be installed in the existing house in each sleeping room, outside of each sleeping room in the immediate vicinity of the bedroom. 2018 IRC R314.2. All smoke detectors shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. 5. Update the carbon monoxide note on sheet A2. Carbon monoxide detectors shall be installed in the existing house outside of each sleeping area in the immediate vicinity of the bedrooms. 2018 IRC R315.3. Carbon monoxide devices shall receive their primary power from the building wiring with a battery backup and shall be interconnected so that the actuation of one alarm will activate all. 2018 IRC R314.4. Smoke detectors and carbon monoxide alarms may be combined. PLUMBING REVIEW COMMENTS: Conditionally Approved No plumbing as part of this submittal, the drawings indicate the laundry room is existing If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |