Permit Number: T22CM04575
Parcel: 129020510

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T22CM04575
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/24/2022 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
08/24/2022 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
08/25/2022 WILDAN BUILDING-COMMERCIAL REVIEW Completed
08/25/2022 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed DRAWINGS REVISED TO DIRECT HAND SINK & FLOOR SINK TO GREASE WASTE.
Floor sinks in the kitchen shall discharge through a grease interceptor. Hand sinks (SK-1) in the kitchen are allowed to connect to the sanitary waste system instead of the grease waste system only if each sink has a sign posted above it stating, "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED." Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson. [Initial comment: The new 3-compartment sink, hand sink, and floor sink in the expansion area do not discharge to grease waste. What operations are happening with these fixtures? Reference: Section 1003.1, IPC 2018.]